Anti-Hu CD158agh PE

Anti-Hu CD158agh PE
Regulatory status
RUO
Antigen
CD158agh
Clone
HP-MA4
Format
PE
Reactivity
Human
Application
FC (QC tested)
Excitation laser
blue (488 nm)
Variant
100 tests
1P-775-T100
In stock

25 tests
1P-775-T025
Out of stock
Variant
0.1 mg
11-261-C100
In stock

0.1 mg
11-261-C100
In stock
Product details
Images
References
Isotype
Mouse IgG2b kappa
Specificity
The mouse monoclonal antibody HP-MA4 recognizes CD158 isoforms KIR2DL1 (CD158a), KIR2DS5 (CD158g), KIR2DS1 (CD158h), and KIRDS3. It does not recognize the isoforms CD158b1,d,f,i,j.
Application
FC (QC tested)
Application details
Flow cytometry: The reagent is designed for analysis of human blood cells using 10 μl reagent / 100 μl of whole blood or 106 cells in a suspension. The content of a vial (1 ml) is sufficient for 100 tests.
Reactivity
Human
Immunogen
Human NK cell line LB2
Other names
KIR2DL1, NKAT, KIR2DS1, KIR2DS3, NKAT7, KIR2DS5, NKAT9, CD158g, CD158h, CD158a
Preparation
The purified antibody is conjugated with R-phycoerythrin (PE) under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Formulation
Stabilizing phosphate buffered saline (PBS) solution containing 15mM sodium azide
Storage and handling
Store in the dark at 2-8°C. Do not freeze. Avoid prolonged exposure to light. Do not use after expiration date stamped on vial label.
Exbio licence note
Unless indicated otherwise, all products are For Research Use Only and not for diagnostic use. In vivo diagnostic or therapeutic applications are strictly forbidden. Products shall not be used for resale or transfer to third parties either as a stand-alone product or as a manufacture component of another product without written consent of EXBIO Praha, a.s. EXBIO Praha, a.s. will not be held responsible for patent infringement or any other violations of intellectual property rights that may occur with the use of the products. Orders for all products are accepted subject to the Term and Conditions available at www.exbio.cz. EXBIO, EXBIO Logo, and all other trademarks are property of EXBIO Praha, a.s. © 2019 EXBIO Praha, a.s. All rights reserved.
1P-775 FC
Flow cytometry analysis (surface staining) of human peripheral blood with anti-CD158a/g/h (HP-MA4) PE.

Product specific references:

Wiernik A, Foley B, Zhang B, Verneris MR, Warlick E, Gleason MK, Ross JA, Luo X, Weisdorf DJ, Walcheck B, Vallera DA, Miller JS: Targeting natural killer cells to acute myeloid leukemia in vitro with a CD16 x 33 bispecific killer cell engager and ADAM17 inhibition. Clin Cancer Res. 2013 Jul 15;19(14):3844-55
PubMed
Variant
100 tests
1P-775-T100
In stock

25 tests
1P-775-T025
Out of stock
Variant
0.1 mg
11-261-C100
In stock

0.1 mg
11-261-C100
In stock